Heat recovery ventilation controller
- Scope
- Complete replacement of a generic control module with a proprietary controller: system architecture, board design, firmware, and a wall panel communicating over RS485.
- Engineering
- Mixed-signal design combining mains switching and low-level analog measurement on a single board. Custom segment display specified and laid out for the unit’s exact indication set.
- Delivered
- Production-ready controller and panel, with design files and behaviour fully owned by the manufacturer.